Brand Name : NANBEI
Model Number : GC-MS 3200
Certification : CE/ISO/SGS/TUV
Place of Origin : China
MOQ : 1/set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 500 set/per day
Delivery Time : 7-10days
Packaging Details : Wooden cases and cartons
Name : Gas Chromatograph – Mass Spectrometer (Quadrupole)
lPower : 220 V, 50 Hz
Temperature : 15℃-35℃
Humidity : 25%-80% RH
Column oven temperature : Room temperature + 10℃-400℃
Temperature stability : ≤±0.03℃
Maximum heating rate : 40℃/min
Maximum run time : 999.99 min
Gas Chromatograph – Mass Spectrometer (Quadrupole) with new ion optics system
Brief introduction of NBXD-8010:
Applications
The excellent performance of the GC-MS 3200 makes it suitable for applications in various fields including food safety, environmental safety, chemicals, among others.

1 Detection of Melamine in Milk
 The detection limit is stable at 0.01 mg/kg. Linearity remains excellent between 0.05 - 50 mg/L. Recovery of added standard is between 85% - 108%. Relative standard deviation is less than 5%. Correlation coefficient is above 0.999. Results comply with GB / T 22388-2008 standard.
2 Analysis of Volatile Organic Compounds (VOC) in Drinking Water or Surface Water
 Using external standard method, range of linearity is 0.5 - 100 μg/L. Correlation coefficient of each component is between 0.993 ~ 0.9992. The lowest detection limit is 0.001 mg/L for vinyl chloride. The instrument shows excellent performance in VOC analysis of drinking water in compliance with EPA method 502.2 and GB5749-2006.
3 Detection of Plasticizer in Liquors
 16 types of phthalates in liquor are analyzed simultaneously. Range of linearity is 0.08 - 1.6 ug/mL. Recovery of added standard is between 70% - 119%. The lowest detection limit achieved is 1.06 ug/kg for DEP. Shows excellent contamination resistance. After 1 month of continuous use, background signal remains within spec.
4 Trace PAHs Detection
 Linear correlation coefficient is more than 0.999 in the concentration range of 0.05 - 0.5 ug /mL.
 Relative standard deviation is less than 6%. The lowest detection quality for benzopyrazole is 0.05 ng.
5 Detection of Organochlorine Pesticide
In ion monitoring mode, the analysis of organochlorine pesticide provides reliable data. Range of linearity is 0.012 - 0.2 ug/mL. Relative standard deviation is less than 10%. Lowest detection concentration reaches 0.012 ug/L.
6 Rapid Semi-quantitative Analysis of Hydrocarbons
7 Qualitative Analysis of Unknown Samples Using Direct Injection Probe


| Working Conditions | |
| l Power | 220 V, 50 Hz | 
| l Temperature | 15℃-35℃ | 
| l Humidity | 25%-80% RH | 
| Specifications | |
| Gas Chromatograph | |
| l Column oven temperature | Room temperature + 10℃-400℃ | 
| l Temperature stability | ≤±0.03℃ | 
| Maximum heating rate | 40℃/min | 
| Maximum run time | 999.99 min | 
| 10-segment programmable temperature control | |
| l Split/splitless inlet (3rd generation EPC) | |
| Maximum temperature: 400℃ | |
| Electronic controlled pressure, flow rate and split ratio | |
| Pressure range: 0-999 kPa | |
| Flow range: 0-200 mL/min | |
| Autosampler (optional) | |
| Mass Spectrometer | |
| l Main Specifications | |
| Mass range | 1.5 - 1024.0 amu | 
| Mass stability | Better than 0.1 amu/48 h | 
| Resolution | Unit mass | 
| Sensitivity |  			 DB-5MS 30m*0.25mm*0.25um fused silica capillary column or similar column. EI source, full scan: (range 100-300 amu). 1 pg OFN S/N≥100:1  |  		
| Maximum scan rate | 10,000 amu/s | 
| Dynamic range | 105 | 
| l Ion source |  			 Electron impact ionization source (EI), standard. Chemical ionization source (CI), optional.  |  		
| Dual filaments | Programmable switch | 
| Maximum filament current | 3 A | 
| Emission current | 10 – 350μA adjustable | 
| Ionization energy | 5 – 150eV adjustable | 
| Ion source temperature | 150 – 320℃ adjustable, individually controlled | 
| l Mass analyzer |  			 Quadrupole. Full scan, selected ion monitoring (SIM) and acquisition. At most 128 groups in SIM mode. At most 128 ions in each group.  |  		
| l Detector | electron multiplier + high-energy dynode back focusing assembly | 
| l GC-MS interface | |
| Individually controlled through transmission cable, 150 – 320℃ adjustable | |
| l Vacuum system | |
| Turbo molecular pump (250 L/s), mechanical pump (180 L/min) | |
| Wide range compound cold cathode gauge | |
| l Data processing system | |
| Hardware | Computer (optional) | 
| Printer | Laser printer (optional) | 
| Software | MS3200RT Real-time data acquisition application and MS3200P data processing application | 
|  			 Optional Accessories 
  |  		|
| DIP 100 liquid/solid direct injection probe assembly | |
| Thermal desorption device | |
| Dynamic headspace sampler | |
| Purge-and-trap sample concentrator | |



                         
| 
                                             | 
                